background image
ASUS GUI RAID Manager: Installation
2-16
2.3
In-band SCSI
The Manager Site should be a Windows NT Workstation or Server
with SNMP service and the GUI RAID Manager installed.
Basic Procedures to Establish the Connection
The following criteria must be met for the Agent Site and Manager
Site:
Checklist for Agent Site
1. The host computer is connected to the RAID controller via the
host SCSI cable (the cable which is used to transfer data between
the host computer and the RAID — there’s no need for an extra
SCSI cable.)
2. The host computer’s operating system has SNMP service
installed.
3. The host computer has the In-band SCSI SNMP agent installed
for the corresponding operating system. (The example described
herein is Windows NT.)
4. The host computer is up and running.
IMPORTANT:
This following applies to Windows NT 4.0 with Service Pack 3: if the
"SNMP Service" is installed after the Service Pack 3 has been installed,
Service Pack 3 must be re-installed in order for the SNMP service to
work properly.