8-59
ASUS PCI-DA2200 User’s Manual
IMPORTANT:
By choosing a time value to enable the "Periodic Drive Check Time", the
controller will poll all of the connected drives in the controller’s drive
channels at the assigned interval. Drive removal will be detected even if
a host does not attempt to access data on the drive.
If the "Periodic Drive Check Time" is set to "Disabled" (the default
setting is "Disabled"), the controller will not be able to detect any drive
removal that occurs after the controller has been powered on. The
controller will only be able to detect drive removal when a host attempts
to access the data on the drive.
SAF-TE Enclosure Monitoring
From the “Drive-side SCSI Parameters” menu, select “Periodic SAF-
TE Device Check Time – Disabled” and then press [Enter]. Use the
arrow keys to choose the desired SAF-TE status check interval.