background image
5-24
Chapter 5: BIOS setup
4GB.PCI.Hole.Granularity.[256.MB]
Allows you to select the granularity of the PCI hole for PCI resource.
Configuration options: [256 MB] [512 MB] [1.0 GB] [2.0 GB]
Memory.Branch.Mode.[Interleave]
Allows you to select the memory branch mode.
Configuration options: [Sequential] [Interleave] [Mirror] [Single channel 0]
Branch.0.Rank.Interleave.[4:1]
Allows you to select the Branch 0 Rank Interleave.
Configuration options: [1:1] [2:1] [4:1]
Branch.0.Rank.Sparing.[Disabled]
Allows you to enable or disable the Branch 0 rank/DIMM Sparing feature. This item
does not appear when the
Memory.Branch.Mode is set to [Mirror].
Configuration options: [Disabled] [Enabled]
Branch.1.Rank.Interleave.[4:1]
Allows you to select the Branch 0 Rank Interleave.
Configuration options: [1:1] [2:1] [4:1]
Branch.1.Rank.Sparing.[Disabled]
Allows you to enable or disable the Branch 0 rank/DIMM Sparing feature. This item
does not appear when the
Memory.Branch.Mode is set to [Mirror].
Configuration options: [Disabled] [Enabled]
Enhanced.x8.Detection.[Enabled]
Allows you to enable or disable the enhanced x8 DRAM UC error detection.
Configuration options: [Disabled] [Enabled]
Force ITK Config Clocking [Disabled]
Allows you to enable or disable the FBD configuration for ITK test suite.
Configuration options: [Disabled] [Enabled]
FBDIMM(s).Thermal.Throttling.[ASUS.MemCool]
Allows you to disable or set the thermal throttling control.
Configuration options: [Open Loop] [Close Loop] [ASUS MemCool Fan] [Disabled]
Set this item to [ASUS MemCool Fan] for a better fan management.
The following item appears when you set the
FBDIMM(s).Thermal.Throttling
to [Open Loop] or [Close Loop].
Open.Loop.Type.[Best.Performance]
Allows you to select the Open Loop Type.
Configuration options: [Best Performance] [Best Acoustic] [User Define]