background image
ASUS AP1600R 1U Rackmount Server
43
Input Characteristics
A.2
Specifications
Output Characteristics
Over-Voltage Protection (OVP)
Input Voltage Range
Min
Nom
Max
Range 1
90V
100V
140V
Range 2
180V
240V
264V
Input Frequency Range
47 Hz to 63 Hz
Maximum Input ac Current
4.96A max. at 100Vac
2.48A max. at 200Vac
2.75A max. at 230Vac, maximum load
Inrush Current
30A cold start
30A warm start
Efficiency
72% min. at nominal input,
maximum load
Output
Load Range
Regulation
Ripple
Voltage
Min
Max
Min
Max
Max
+5V
1.0A
12.0A
-4%
+5%
50mVp-p
+12V1
1.5A
16.0A
-4%
+5%
120mVp-p
+12V2
0.5A
16.0A
-4%
+5%
120mVp-p
-12V
0A
0.5A
-5%
+9%
120mVp-p
+5VSB
0.1A
2.0A
-4%
+5%
50mVp-p
+3V3
1.5A
16.0A
-3%
+5%
50mVp-p
Output Voltage
Maximum Voltage
+5V
6.2V
+12V
14.5V
+3.3V
4.5V
+5VSB
6.5V
-12V
-14.5V
NOTE
The power supply will shut down and latch off for shorting +5V,
+12V, -12V, or +3.3V. By shorting +5VSB, the power supply can
latch down or automatically recover when the fault condition is
removed. This requires disconnecting then re-connecting the AC
power plug.