background image
ReportNo. 019L036E
Page : 45 of 48
Version:1.0
13.10.
Test Data of Voltage Dips and Interruption
Date of Test
October 5, 2001
Test Room
No.3 Shielded Room
Test Mode
Mode 1: PIII 1.2GHz/133MHz, 1600*1200/85Hz
Product
PC System
Test Condition
Voltage Dips and Interruption
Voltage Dips and
Interruption
Reduction(%)
Angle
Test Duration
(Periods)
Required
Performance
Criteria
Observation
Test Result
>95(0V)
0
0.5
B
A
PASS
>95(0V)
45
0.5
B
A
PASS
>95(0V)
90
0.5
B
A
PASS
>95(0V)
135
0.5
B
A
PASS
>95(0V)
180
0.5
B
A
PASS
>95(0V)
225
0.5
B
A
PASS
>95(0V)
270
0.5
B
A
PASS
>95(0V)
315
0.5
B
A
PASS
30(161V)
0
25
C
A
PASS
30(161V)
45
25
C
A
PASS
30(161V)
90
25
C
A
PASS
30(161V)
135
25
C
A
PASS
30(161V)
180
25
C
A
PASS
30(161V)
225
25
C
A
PASS
30(161V)
270
25
C
A
PASS
30(161V)
315
25
C
A
PASS
>95(0V)
0
250
C
C
PASS
>95(0V)
45
250
C
C
PASS
>95(0V)
90
250
C
C
PASS
>95(0V)
135
250
C
C
PASS
>95(0V)
180
250
C
C
PASS
>95(0V)
225
250
C
C
PASS
>95(0V)
270
250
C
C
PASS
>95(0V)
315
250
C
C
PASS
Criteria judgment of Test result:
Meet criteria A: No abnormalities were observed during and directly after the test.
Meet criteria B: Operate as intended after the test
Meet criteria C: Loss/Error of function
Additional Information
EUT stopped operation and could be reset by operator.
No false alarms or other malfunctions were observed during or after the test.