background image
ReportNo. 019L036E
Page : 44 of 48
Version:1.0
13.9.
Test Data of Power Frequency Magnetic Field
Date of Test
October 5, 2001
Test Room
No.3 Shielded Room
Test Mode
Mode 1: PIII 1.2GHz/133MHz, 1600*1200/85Hz
Product
PC System
Test Condition
Power Frequency Magnetic Field (Performance criteria: A)
Polarization
Frequency
(Hz)
Magnetic Strength
(A/m)
Observation
Test Result
X Orientation
50
1
Normal Function
PASS
Y Orientation
50
1
Normal Function
PASS
Z Orientation
50
1
Normal Function
PASS
Criteria judgment of Test result:
Meet criteria A: No abnormalities were observed during and directly after the test.
Meet criteria B: Operate as intended after the test
Meet criteria C: Loss/Error of function
Additional Information
EUT stopped operation and could / could not be reset by operator at
kV.
No false alarms or other malfunctions were observed during or after the test.