background image
ReportNo. 019L036E
Page : 43 of 48
Version:1.0
13.8.
Test Data of Conducted Susceptibility
Date of Test
October 5, 2001
Test Room
No.3 Shielded Room
Test Mode
Mode 1: PIII 1.2GHz/133MHz, 1600*1200/85Hz
Product
PC System
Test Condition
Conducted Susceptibility (Performance Criteria: A)
Frequency Range
(MHz)
Voltage Applied
dBuV(V)
Inject Method
Tested Port of
EUT
Observation
Result
0.15 ~ 80
130(3V)
CDN 1
AC IN
Normal Function
PASS
0.15 ~ 80
130(3V)
CDN 1
Signal Line
Normal Function
PASS
Criteria judgment of Test result:
Meet criteria A: No abnormalities were observed during and directly after the test.
Meet criteria B: Operate as intended after the test
Meet criteria C: Loss/Error of function
Additional Information
EUT stopped operation and could / could not be reset by operator at
kV.
No false alarms or other malfunctions were observed during or after the test.