ReportNo. 019L036E
Page : 42 of 48
Version:1.0
13.7.
Test Data of Surge
Date of Test
October 5, 2001
Test Room
No.3 Shielded Room
Test Mode
Mode 1: PIII 1.2GHz/133MHz, 1600*1200/85Hz
Product
PC System
Test Condition
Surge (Performance Criteria: A)
Inject
Line
Polarity Angle
Voltage
kV
Time
Interval
(Second)
Inject
Method
Observation
Result
L-N
¡Ó
0
1kV
60
Direct
Normal Function
Pass
L-N
¡Ó
90
1kV
60
Direct
Normal Function
Pass
L-N
¡Ó
180
1kV
60
Direct
Normal Function
Pass
L-N
¡Ó
270
1kV
60
Direct
Normal Function
Pass
L-PE
¡Ó
0
2kV
60
Direct
Normal Function
Pass
L-PE
¡Ó
90
2kV
60
Direct
Normal Function
Pass
L-PE
¡Ó
180
2kV
60
Direct
Normal Function
Pass
L-PE
¡Ó
270
2kV
60
Direct
Normal Function
Pass
N-PE
¡Ó
0
2kV
60
Direct
Normal Function
Pass
N-PE
¡Ó
90
2kV
60
Direct
Normal Function
Pass
N-PE
¡Ó
180
2kV
60
Direct
Normal Function
Pass
N-PE
¡Ó
270
2kV
60
Direct
Normal Function
Pass
Criteria judgment of Test result:
Meet criteria A: No abnormalities were observed during and directly after the test.
Meet criteria B: Operate as intended after the test
Meet criteria C: Loss/Error of function
Additional Information
EUT stopped operation and could / could not be reset by operator at
kV.
No false alarms or other malfunctions were observed during or after the test.