ReportNo. 019L036E
Page : 41 of 48
Version:1.0
13.6.
Test Data of Electrical Fast Transient
Date of Test
October 5, 2001
Test Room
No.3 Shielded Room
Test Mode
Mode 1: PIII 1.2GHz/133MHz, 1600*1200/85Hz
Product
PC System
Test Condition
Electrical Fast Transient (Performance Criteria: B)
Inject
Line
Polarity
Voltage
kV
Inject
Time
(Second)
Inject
Method
Observation
Result
L
¡Ó
1kV
60
Direct
Normal Function
Pass
N
¡Ó
1kV
60
Direct
Normal Function
Pass
PE
¡Ó
1kV
60
Direct
Normal Function
Pass
L+N
¡Ó
1kV
60
Direct
Normal Function
Pass
L+PE
¡Ó
1kV
60
Direct
Normal Function
Pass
N+PE
¡Ó
1kV
60
Direct
Normal Function
Pass
L+N+PE
¡Ó
1kV
60
Direct
Normal Function
Pass
DataLine
(LAN)
¡Ó
0.5kV
60
Clamp
Normal Function
Pass
Criteria judgment of Test result:
Meet criteria A: No abnormalities were observed during and directly after the test.
Meet criteria B: Operate as intended after the test
Meet criteria C: Loss/Error of function
Additional Information
EUT stopped operation and could / could not be reset by operator at
kV.
No false alarms or other malfunctions were observed during or after the test.