ReportNo. 019L036E
Page : 39 of 48
Version:1.0
13.4.
Test Data of Electrostatic Discharge
Date of Test
October 5, 2001
Test Room
No.3 Shielded Room
Test Mode
Mode 1: PIII 1.2GHz/133MHz, 1600*1200/85Hz
Product
PC System
Test Condition
Electrostatic Discharge (Performance Criteria: B)
Test point
Polarity
Number of
Discharges
Observation
Result
Seams
+/-8kV Air
10
Normal function
PASS
Switch
+/-4kV Air
10
Normal function
PASS
Knobs
+/-4kV Con
10
Normal function
PASS
Metal Plate
+/-4kV Con
10
Normal function
PASS
Screws
+/-4kV Con
10
Normal function
PASS
H.C.P.
+/-4kV
10
Normal function
PASS
V.C.P.
+/-4kV
10
Normal function
PASS
Criteria judgment of Test result:
Meet criteria A: No abnormalities were observed during and directly after the test.
Meet criteria B: Operate as intended after the test
Meet criteria C: Loss/Error of function
Additional Information
EUT stopped operation and could / could not be reset by operator at
kV.
No false alarms or other malfunctions were observed during or after the test.