background image
ReportNo. 019L036E
Page : 37 of 48
Version:1.0
EUT: PC SYSTEM
Tested by: MILLER
Test category: Class D Steady State (European limits)
Test Margin: 100
Test date: 2001/10/8
Start time: PM 10:37:28
End time: PM 10:40:09
Test duration (min): 2.5
Data file name: H-000570.cts_data
Comment:
M/N:Terminator Tualatin
Customer:
ASUS
Test Result: Pass
Source qualification:
Normal
Highest parameter values during test:
V_RMS (Volts):
229.65
I_Peak (Amps):
0.756
I_RMS (Amps):
0.297
I_Fund (Amps):
0.222
Crest Factor:
2.568
Power (Watts):
50
Power Factor:
0.738
Harm#
Harmonics
Limit
% of Limit
Status
2
0.003
3
0.174
--
--
Pass
4
0.001
5
0.097
--
--
Pass
6
0.002
7
0.038
--
--
Pass
8
0.001
9
0.021
--
--
Pass
10
0.001
11
0.016
--
--
Pass
12
0.001
13
0.008
--
--
Pass
14
0.001
15
0.008
--
--
Pass
16
0.001
17
0.006
--
--
Pass
18
0.001
19
0.005
--
--
Pass
20
0.001
21
0.004
--
--
Pass
22
0.001
23
0.003
--
--
Pass
24
0.001
25
0.003
--
--
Pass
26
0.001
27
0.003
--
--
Pass
28
0.001
29
0.002
--
--
Pass
30
0.001
31
0.002
--
--
Pass
32
0.001
33
0.002
--
--
Pass
34
0.001
35
0.002
--
--
Pass
36
0.001
37
0.002
--
--
Pass
38
0.001
39
0.002
--
--
Pass
40
0.001
Note :
1.Dynamic limits were applied for this test. The highest harmonics values in the above table may not occur at the same window as the
maximum harmonics/limit ratio.
2:According to EN61000-3-2 pavagraph 7.4 the limits given in table 3 are valid for all applications having an active input power >75W.
3.” -- “ mean the limit is not applicable/