background image
ReportNo. 019L036E
Page : 36 of 48
Version:1.0
13.3.
Test Data of Power Harmonics
Date of Test
October 5, 2001
Test Room
No.3 Shielded Room
Test Mode
Mode 1: PIII 1.2GHz/133MHz, 1600*1200/85Hz
Product
PC System
Test Condition
Power Harmonics (Classification : Class D)
EUT: PC SYSTEM
Tested by: MILLER
Test category: Class D Steady State (European limits)
Test Margin: 100
Test date: 2001/10/8
Start time: PM 10:37:28
End time: PM 10:40:09
Test duration (min): 2.5
Data file name: H-000570.cts_data
Comment: M/N:Terminator Tualatin
Customer: ASUS
Test Result: Pass
Source qualification: Normal
Current & voltage waveforms
It is 0.0% outside Class-D envelope
-1.5
-1.0
-0.5
0.0
0.5
1.0
1.5
-300
-200
-100
0
100
200
300
Current
(Amps)
Voltage
(Volts)
Harmonics and Class D limit line
European Limits
0.000
0.025
0.050
0.075
0.100
0.125
0.150
0.175
Current
RMS(Amps)
Harmonic #
4
8
12
16
20
24
28
32
36
40
Test result:
Pass
Worst harmonic was #0 with 0.00 % of the limit.
Current Test Result Summary (Run time)