background image
ReportNo. 019L036E
Page : 28 of 48
Version:1.0
10.4.
Test Procedure
The EUT and its load are placed on a table which is 0.8 meter above a metal ground plane
measured at least 1m*1m min. The test magnetic field shall be placed at central of the induction
coil.
The test magnetic Field shall be applied 10minutes by the immersion method to the EUT. And the
induction coil shall be rotated by 90
° in order to expose the EUT to the test field with different
orientation (X, Y, Z Orientations).
10.5.
Test Specification
According to EN 61000-4-8:1993
10.6.
Test Result
The measurement of the Power Frequency Magnetic Field was investigated and test result was shown
in section 13. The acceptance criterion was met and the EUT passed the test.