ReportNo. 019L036E
Page : 26 of 48
Version:1.0
9.3.
Test Level
Item
Environmental Phenomena Units
Test Specification
Performance Criteria
Signal Ports and Telecommunication Ports
Radio-Frequency
Continuous Conducted
MHz
V (rms, Un-modulated)
% AM (1kHz)
0.15-80
3
80
A
Input DC Power Ports
Radio-Frequency
Continuous Conducted
MHz
V (rms, Un-modulated)
% AM (1kHz)
0.15-80
3
80
A
Input AC Power Ports
Radio-Frequency
Continuous Conducted
MHz
V (rms, Un-modulated)
% AM (1kHz)
0.15-80
3
80
A
9.4.
Test Procedure
The EUT are placed on a table that is 0.8 meter height, and a Ground reference plane on the table,
EUT are placed upon table and use a 10cm insulation between the EUT and Ground reference
plane.
For Signal Ports and Telecommunication Ports
The disturbance signal is through a coupling and decoupling networks (CDN) or EM-clamp
device couples to the signal and Telecommunication lines of the EUT.
For Input DC and AC Power Ports
The EUT is connected to the power mains through a coupling and decoupling networks for power
supply lines. And directly couples the disturbances signal into EUT.
Used CDN-M2 for two wires or CDN-M3 for three wires.
All the scanning conditions are as follows:
Condition of Test
Remarks
1. Field Strength
130dBuV(3V) Level 2
2. Radiated Signal
AM 80% Modulated with 1kHz
3. Scanning Frequency
0.15MHz – 80MHz
4 Dwell Time
3 Seconds
5. Frequency step size
∆ f :
1%
6. The rate of Swept of Frequency
1.5 x 10
-3 decades/s
9.5.
Test Specification
According to EN 61000-4-6:1996
9.6.
Test Result
The measurement of the Conducted Susceptibility was investigated and test result was shown in
section 13. The acceptance criterion was met and the EUT passed the test.