background image
ReportNo. 019L036E
Page : 25 of 48
Version:1.0
9.
Conducted Susceptibility (CS)
9.1.
Test Equipment
Item
Instrument
Manufacturer
Type No/Serial No.
Last Calibration
1
Signal Generator
IFR
2023B / 202302/581
May, 2001
2
Power Amplifier
A & R
500A100AM3 /29369
Aug., 2001
3
Power Amplifier
SCHAFFNER
CBA9413B / 0006
June, 2001
4
CDN 1
Schwarzbeck
L801 M2/3 / 1549
Jun, 2001
5
CDN 2
Schwarzbeck
L801 S1 / 1574
Jun, 2001
6
CDN 3
Schwarzbeck
L801 AF4 / 1064
Jun, 2001
7
CDN 4
Schwarzbeck
L801 AF8 / 1070
Jun, 2001
8
CDN 5
FCC
FCC-801-S9 / 9837
Jun, 2001
9
CDN 6
FCC
FCC-801-S15 / 9838
Jun, 2001
10
CDN 7
FCC
FCC-801-S25 / 9839
Jun, 2001
11
50 ohm Terminator
RES-NET
RCX6BM
Jun, 2001
12
6dB Attenuator
BIRD
RFA250NFF10
Jun, 2001
13
EM Clamp
Schwarzbeck
KEMZ 801 / 15928
Jun, 2001
14
No.2 EMC Fully Chamber
N/A
Note: All equipment upon which need to calibrated are with calibration period of 1 year.
9.2.
Test Setup
Aux
equipment
EUT
CDN
RF-Generator
T2
Ground Reference Plane
Non - Conducted Table
CDN
Aux
equipment
T
10c m
PA