8.4.
Test Procedure
The EUT and its load are placed on a table that is 0.8 meter above a metal ground plane measured
1m*1m min. and 0.65mm thick min. And projected beyond the EUT by at least 0.1m on all sides.
The length of power cord between the coupling device and the EUT shall be 2m or less.
For Input and Output AC Power or DC Input and DC Output Power Ports:
The EUT is connected to the power mains through a coupling device that directly couples the
Surge interference signal.
The surge noise shall be applied synchronized to the voltage phase at 0
0, 900, 1800, 2700 and the
peak value of the a.c. voltage wave. (Positive and negative)
Each of Line-Earth and Line-Line is impressed with a sequence of five surge voltages with
interval of 1 min.
8.5.
Test Specification
According to EN 61000-4-5:1995
8.6.
Test Result
The measurement of the Surge was investigated and test result was shown in section 13. The
acceptance criterion was met and the EUT passed the test.