ReportNo. 019L036E
Page : 22 of 48
Version:1.0
7.4.
Test Procedure
The EUT and load are placed on a table that is 0.8 meter above a metal ground plane measured
1m*1m min. and 0.65mm thick min. And projected beyond the EUT by at least 0.1m on all sides.
For Signal Ports and Telecommunication Ports:
The EFT interference signal is through a coupling clamp device couples to the signal and
control lines of the EUT with burst noise for 1min.
For Input DC and AC Power Ports:
The EUT is connected to the power mains through a coupling device that directly couples the
EFT interference signal.
Each of the Line and Neutral conductors is impressed with burst noise for 1 min.
The length of power cord between the coupling device and the EUT shall be 1m.
7.5.
Test Specification
According to EN 61000-4-4:1995
7.6.
Test Result
The measurement of the Electrical Fast Transient/Burst was investigated and test result was
shown in section 13. The acceptance criterion was met and the EUT passed the test.