background image
ReportNo. 019L036E
Page : 21 of 48
Version:1.0
7.
Electrical Fast Transient/Burst (EFT/B)
7.1.
Test Equipment
Item Instrument
Manufacturer
Type No/Serial No.
Last Calibration
1
Fast Transient/Burst
Generator
SCHAFFNER
BEST
S/N: 300035-008SC
Jun., 2001
2
No.3 Shielded Room
N/A
Note: All equipment upon which need to calibrated are with calibration period of 1 year.
7.2.
Test Setup
7.3.
Test Level
Item
Environmental Phenomena Units
Test Specification
Performance Criteria
Signal Ports and Telecommunication Ports
Fast Transients Common
Mode
kV (Peak)
Tr/Ts ns
Rep. Frequency kHz
0.5
5/50
5
B
Input DC Power Ports
Fast Transients Common
Mode
kV (Peak)
Tr/Ts ns
Rep. Frequency kHz
0.5
5/50
5
B
Input AC Power Ports
Fast Transients Common
Mode
kV (Peak)
Tr/Ts ns
Rep. Frequency kHz
1
5/50
5
B
EUT
Load
Personal
Compute
Non - Conducted Table
80cm
Ground
AC Power Line to
Coupling Clamp
EFT/Burst
Generator