ReportNo. 019L036E
Page : 20 of 48
Version:1.0
6.4.
Test Procedure
The EUT and load, which are placed on a table that is 0.8 meter above ground, are placed with
one coincident with the calibration plane such that the distance from antenna to the EUT was 3
meters.
Both horizontal and vertical polarization of the antenna and four sides of the EUT are set on
measurement.
In order to judge the EUT performance, a CCD camera is used to monitor EUT screen.
All the scanning conditions are as follows:
Condition of Test
Remarks
EN 55024:1998
1. Field Strength
3 V/M Level 2
2. Radiated Signal
AM 80% Modulated with 1kHz
3. Scanning Frequency
80MHz - 1000MHz
4 Dwell Time
3 Seconds
5. Frequency step size
∆ f :
1%
6. The rate of Swept of Frequency
1.5 x 10
-3 decades/s
6.5.
Test Specification
According to EN 61000-4-3:1995
6.6.
Test Result
The measurement of the radiated susceptibility was investigated and test result was shown in
section 13. The acceptance criterion was met and the EUT passed the test.