background image
ReportNo. 019L036E
Page : 19 of 48
Version:1.0
6.
Radiated Susceptibility (RS)
6.1.
Test Equipment
Item
Instrument
Manufacturer
Type No/Serial No.
Last Calibration
1
Signal Generator
IFR
2023B / 202302/581
May, 2001
2
Power Amplifier
A & R
500A100AM3 /29369
Aug., 2001
3
Power Amplifier
SCHAFFNER
CBA9413B / 0006
June, 2001
4
Field Strength Sensor
SCHAFFNER
EMC 20 / Y-0028/ Z-0003
June, 2001
5
Power Antenna
SCHWARZBECK
VULB 9166 / 1073
Sep., 2001
6
Power Meter
BOONTON
4232A / 42201
May, 2001
7
No.2 EMC Fully Chamber
July, 2001
Note: All equipment upon which need to calibrated are with calibration period of 1 year.
6.2.
Test Setup
6.3.
Test Level
Item
Environmental Phenomena Units
Test Specification
Performance Criteria
Enclosure Port
Radio-Frequency
Electromagnetic Field
Amplitude Modulated
MHz
V/m(Un-modulated, rms)
% AM (1kHz)
80-1000
3
80
A
EUT
Sensor
80cm
3 m
1m
Full-Anechoic Chamber
Power
Amplifier
Signal Generator
Field Meter
Computer
controller
camera system
Camera
Monitor
Antenna
Mast
Load
Power Meter