background image
ReportNo. 019L036E
Page : 13 of 48
Version:1.0
3.
Radiated Emission
3.1.
Test Equipment
The following test equipment are used during the radiated emission test:
Test Site
Equipment
Manufacturer
Model No./Serial No.
Last Cal.
X
Test Receiver
R & S
ESVS 10 / 834468/003
July, 2001
X
Spectrum
Analyzer
Advantest
R3162/ 00803480
May, 2001
X
Pre- Amplifier
Advantest
BB525C/ 3307A01812
May, 2001
X
Bilog Antenna
SCHAFFNER
CBL6112B / 2697
Nov., 2000
Site # 1
X
Test Receiver
R & S
ESCS 30 / 836858/022
Nov., 2001
X
Spectrum
Analyzer
Ad vantest
3162 / 100803466
May, 2001
X
Pre- Amplifier
Advantest
BB525C/3307A01814
May, 2001
X
Bilog Antenna
SCHAFFNER
CBL6112B / 2705
Oct., 2001
X
Horn Antenna
ETS
3115 / 0005 -6160
July, 2001
Site # 2
X
Pre- Amplifier
QTK
QTK - AMP - 01/ 0001
July, 2001
Note:
1. All equipments that need to calibrate are with calibration period of 1 year.
2. Mark “X” test instruments are used to measure the final test results.
3.2.
Test Setup
EUT
FRP Dome
Test
Receiver
Antenna Mast
Broadband or Dipole
Antenna
Antenna height can be
moved from 1m to 4m.
To Controller
To Receiver
Fully Metal Mesh Ground Plane
Non-Conducted Table
10m
1m to 4m
80cm